QR Code QR Code
Post Offer Free
Hefei Fanyuan Instrument Co.,ltd
Hefei Fanyuan Instrument Co.,ltd  

Gold Index: 159055

You are here: home  > Fabric and Garment Testing  > Fabric Tester  > Physiological Thermal and Water-Vapor Resistance Tester

Physiological Thermal and Water-Vapor Resistance Tester 

Price: 1.0 USD 
Payment Terms: T/T,L/C,D/A,WU 
Place of Origin: Anhui, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: DW259A
Production Capacity: 100Pcs
Delivery Date: 3-4 weeks
Power: Electric
MODEL: DW259A
Voltage:: 220V,60HZ
Net weight: 350 KG
Display: LCD
H.S.CODE: 90248000
Means of Transport: Ocean,Land,Air
Packing: plywood package
Usage: Textile Testing Instrument
Brand Name: FYI
Brand : FYI: Color : White
Production capacity: 100sets
Gross weight : 400 kG: Dimension :1200×1500×2200mm
Certificate: CE ,CNAS

1 Simulation Human Skin Sweat Evaporation Test
2.CE,CNAS calibration certificate
3. Free for 12 months maintainence
4.LCD display

Simulation Human Skin Sweat Evaporation Test

MODEL NO.

DW259A Simulation Human Skin Sweat Evaporation Test

APPLICATION 

DW259A Simulation Human Skin Sweat Evaporation Test is often referred to as "skin model" to produce accurate, repeatable measurements of thermal resistance and water vapor resistance of textiles, fabrics, films, coatings, foams and leather including multilayer assemblies, such as clothing, quilts, sleeping bags, upholstery and similar textile or textile-like products under steady-state conditions.

The specimens to be tested is placed on an electronically heated porous plate with conditioned air ducted to flow across and parallel to its upper surface.

Thermal resistance(Rct): a quantity specific to textile materials or composites which determine the dry heat flux across a given area in response to a steady applied temperature gradient, expressed in square meters kelvin per watt.

Rct=(Tm-Ta)*A/(H-ΔHc)

Tm: the temperature of the measuring unit, in degree Celsius;

Ta: the air temperature in the test enclosure, in degree Celsius;

A: the area of the measuring unit, in square meters;

H: the heating power supplied to the measuring unit, in watts;

ΔHc: the correction term for heating power;

Water vapor resistance(Ret): a quantity specific to textile materials or composites which determines the "latent" evaporative heat flux across a given area in response to a steady applied water-vapor pressure gradient, expressed in square meters pascal per watt.

Ret=(Pm-Pa)*A/(H-ΔHe)

Pm: the saturation water-vapour partial pressure, in pascals, on the surface of the measuring unit at temperature Tm;

Pa: the water-vapor partial pressure of the air in the test enclosure at temperature Ta;

A: the area of the measuring unit, in square meters;

H: the heating power supplied to the measuring unit, in watts;

ΔHe: the correction term for heating power for the measurement of water-vapor resistance Ret;

Water-vapor permeability index, imt: ratio of thermal and water-vapor resistance;

imt=S*(Rct/Ret)

S equals to 60Pa/k;

Water vapor permeability, Wd: characteristic of a textile material or composite;

Wd= 1/(Ret*ФTm);

ФTm: the latent heat of vaporization of water at the temperature Tm of the measuring unit;

For example, When Tm=35℃, ФTm=0.672W·h/g.

 

Ventilated Sweating Guarded Hotplate

RELATED STANDARDS  

 

STANDARDS

GB/T 11048

ASTM F1868

ISO 11092

ASTM D1868

ASTM D1518

Note: this Simulation Human Skin Sweat Evaporation Test can conform to but not limit to the standards above, for more standards conformance, please contact us.

FEATURES

l        Use a large touch panel (OMRON,Japan) to display and a microcomputer to control and deal with data automatically;

2        Display measuring results and dynamic curves;

3       In-built programmable testing programs, meeting requirements of related GB/T, ISO standards;

4        With lateral and lower thermal guard rings;

5        Copper test plate and guards with ultra-stable resistance wire heating for uniform heat flux;

The coefficient of radiation of the test plate surface is greater than 0.4, measured at 20℃, between the wavelengths 8 μm to 14 μm, with the primary beam perpendicular to the plate surface and the reflection hemispherical.

6        Use a step motor to move the test plate and thermal guards up or down, stably and accurately;

7       Variable speed fans and air velocity sensor;

8        Use a closed loop control system to supply water automatically and precisely;

9        Use PLC as central control system and an closed loop control system to control temperature and humidity automatically;

l0        Use the surface evaporation method to produce water vapor from saturated steam;

11       Sweating guarded hotplate system is compactly designed so it easily fits into climate-controlled chamber. If available, it can be moved out of the existing climate-controlled chamber and the chamber can be replaced;

 

KEY SPECIFICATION

l        Test method                                         Sweating guarded-hotplate

2        Display mode                                        LCD touch panel

3        Measurable results                                    Thermal resistance Rct,

water-vapor resistance Ret, water-vapor permeability index imt, water vapor permeability Wd, partial discharge (corona), thermal transmittance

4        Measuring range of Rct (thermal resistance)                 0.015~2.0m2K/W

5        Measuring range of Ret (water vapor resistance)              5~1000m2Pa/W

6        Test plate size                                         250×250×3mm (L×W×H)

7        Width of thermal guard ring                              125mm

9        Range & accuracy of measuring temperature                 15℃~50℃±0.1℃

10       Range & accuracy of measuring humidity                   30%RH~98%RH±2%RH

11        Range & accuracy of controlling temperatures of measuring unit  20℃~85℃±0.1℃

l2        Up/down range of porous melt plate and thermal guard         0~50mm 

l3        Accuracy of feeding water                                ±0.5mm

14        Inner dimensions of climate controlled chamber               820×820×1100mm (L×W×H)

l5        Temperature range & accuracy in climate controlled chamber   15℃~50℃±0.1℃

16       Humidity range & accuracy in climate controlled chamber      30%RH~98%RH±2%RH

17       Air velocity                                           0.01~2m/s±0.05m/s

l8        Frequency of measuring air speed                          200Hz

l9        Power supply                                          AC 220V 50HZ 1500W

20       Dimensions                                           1200×1500×2200mm (L×W×H)

21        Weight                                               approx. 400kg

 

STANDARD CONFIGURATION

 

No.

Item

Quantity

1

Main   machine

1set

2

Cellulose   membrane used in measuring water vapor resistance

2pcs




Factory show :

 

 

 


bigPhoto
 Ms. Tracy

Tel: 86-551-68105003
Mobile: 133 1686 0330
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Hefei Fanyuan Instrument Co.,ltd [China (Mainland)]


Business Type:Manufacturer, Trading Company, Distributor/Wholesaler
City: Hefei
Province/State: Anhui
Country/Region: China (Mainland)

Follow Us: Follow us on facebook Follow us on linkedin Follow us on Twitter

You May Like: